{"id":85226,"date":"2026-02-11T20:27:23","date_gmt":"2026-02-11T23:27:23","guid":{"rendered":"https:\/\/tech.einnews.com\/article\/891547346"},"modified":"2026-02-11T20:27:23","modified_gmt":"2026-02-11T23:27:23","slug":"a-novel-approach-to-sub-transmission-islanding-protection-extending-dgp-technology-to-69kv-systems","status":"publish","type":"post","link":"https:\/\/new7.shop\/zerocostfreehost\/index.php\/2026\/02\/11\/a-novel-approach-to-sub-transmission-islanding-protection-extending-dgp-technology-to-69kv-systems\/","title":{"rendered":"A Novel Approach to Sub-transmission Islanding Protection: Extending DGP Technology to 69kV Systems"},"content":{"rendered":"<div><img data-opt-id=758893364  fetchpriority=\"high\" decoding=\"async\" src=\"data:image\/gif;base64,R0lGODlhAQABAIAAAAAAAP\/\/\/ywAAAAAAQABAAACAUwAOw==\" fifu-lazy=\"1\" fifu-data-sizes=\"auto\" fifu-data-srcset=\"https:\/\/i3.wp.com\/img.tdworld.com\/files\/base\/ebm\/tdworld\/image\/2026\/01\/6972a123c493abb39fa48711-cei_and_gridedge__substation_electrical_worker.png?auto=format%2Ccompress&fit=fill&fill=blur&w=1200&h=630&ssl=1&w=75&resize=75&ssl=1 75w, https:\/\/i3.wp.com\/img.tdworld.com\/files\/base\/ebm\/tdworld\/image\/2026\/01\/6972a123c493abb39fa48711-cei_and_gridedge__substation_electrical_worker.png?auto=format%2Ccompress&fit=fill&fill=blur&w=1200&h=630&ssl=1&w=100&resize=100&ssl=1 100w, https:\/\/i3.wp.com\/img.tdworld.com\/files\/base\/ebm\/tdworld\/image\/2026\/01\/6972a123c493abb39fa48711-cei_and_gridedge__substation_electrical_worker.png?auto=format%2Ccompress&fit=fill&fill=blur&w=1200&h=630&ssl=1&w=150&resize=150&ssl=1 150w, https:\/\/i3.wp.com\/img.tdworld.com\/files\/base\/ebm\/tdworld\/image\/2026\/01\/6972a123c493abb39fa48711-cei_and_gridedge__substation_electrical_worker.png?auto=format%2Ccompress&fit=fill&fill=blur&w=1200&h=630&ssl=1&w=240&resize=240&ssl=1 240w, https:\/\/i3.wp.com\/img.tdworld.com\/files\/base\/ebm\/tdworld\/image\/2026\/01\/6972a123c493abb39fa48711-cei_and_gridedge__substation_electrical_worker.png?auto=format%2Ccompress&fit=fill&fill=blur&w=1200&h=630&ssl=1&w=320&resize=320&ssl=1 320w, https:\/\/i3.wp.com\/img.tdworld.com\/files\/base\/ebm\/tdworld\/image\/2026\/01\/6972a123c493abb39fa48711-cei_and_gridedge__substation_electrical_worker.png?auto=format%2Ccompress&fit=fill&fill=blur&w=1200&h=630&ssl=1&w=500&resize=500&ssl=1 500w, https:\/\/i3.wp.com\/img.tdworld.com\/files\/base\/ebm\/tdworld\/image\/2026\/01\/6972a123c493abb39fa48711-cei_and_gridedge__substation_electrical_worker.png?auto=format%2Ccompress&fit=fill&fill=blur&w=1200&h=630&ssl=1&w=640&resize=640&ssl=1 640w, https:\/\/i3.wp.com\/img.tdworld.com\/files\/base\/ebm\/tdworld\/image\/2026\/01\/6972a123c493abb39fa48711-cei_and_gridedge__substation_electrical_worker.png?auto=format%2Ccompress&fit=fill&fill=blur&w=1200&h=630&ssl=1&w=800&resize=800&ssl=1 800w, https:\/\/i3.wp.com\/img.tdworld.com\/files\/base\/ebm\/tdworld\/image\/2026\/01\/6972a123c493abb39fa48711-cei_and_gridedge__substation_electrical_worker.png?auto=format%2Ccompress&fit=fill&fill=blur&w=1200&h=630&ssl=1&w=1024&resize=1024&ssl=1 1024w, https:\/\/i3.wp.com\/img.tdworld.com\/files\/base\/ebm\/tdworld\/image\/2026\/01\/6972a123c493abb39fa48711-cei_and_gridedge__substation_electrical_worker.png?auto=format%2Ccompress&fit=fill&fill=blur&w=1200&h=630&ssl=1&w=1280&resize=1280&ssl=1 1280w, https:\/\/i3.wp.com\/img.tdworld.com\/files\/base\/ebm\/tdworld\/image\/2026\/01\/6972a123c493abb39fa48711-cei_and_gridedge__substation_electrical_worker.png?auto=format%2Ccompress&fit=fill&fill=blur&w=1200&h=630&ssl=1&w=1600&resize=1600&ssl=1 1600w\" fifu-data-src=\"https:\/\/i3.wp.com\/img.tdworld.com\/files\/base\/ebm\/tdworld\/image\/2026\/01\/6972a123c493abb39fa48711-cei_and_gridedge__substation_electrical_worker.png?auto=format%2Ccompress&fit=fill&fill=blur&w=1200&h=630&ssl=1\" class=\"ff-og-image-inserted\"><\/div>\n<h2>A New Paradigm: Distributed Generation Permissive<\/h2>\n<p>A promising alternative to these traditional methods is the Distributed Generation Permissive (DGP) system, a form of Powerline Conducted Permissive (PLCP) signal. The DGP approach, as described in a <a href=\"https:\/\/www.researchgate.net\/publication\/327191334_A_New_Approach_to_Anti-Islanding_Design_Installation_and_In-Service_Experience\" target=\"_blank\" rel=\"noopener\">2018 IEEE paper by Sadan and Renz<\/a>, utilizes the power lines themselves as the communication medium. A transmitter at the substation continuously sends a permissive signal to receivers at each DER\u2019s point of common coupling (PCC). If the connection to the main grid is lost, the permissive signal is interrupted and the receiver at the DER initiates a trip, which disconnects the DER from the islanded section of the grid.<\/p>\n<p>This permissive signal approach is inherently fail-safe \u2014 any interruption, whether from an actual islanding event or a deliberate command from the utility, results in the disconnection of the DER. It provides high dependability with a low probability of false trips.<\/p>\n<h2>The Technology Behind DGP&nbsp;<\/h2>\n<p>The effectiveness of the DGP system stems from several innovative technological advancements that distinguish it from older Power Line Carrier (PLC) systems. These innovations address the challenges of signal integrity, noise and distance in the harsh electrical environment of power distribution lines.<\/p>\n<h2>Advanced Coupling and Signal Transmission<\/h2>\n<p>At the heart of the system is the method used to inject and receive the high-frequency permissive signal onto the power lines. For medium-voltage applications, DGP employs a specially designed capacitive coupler that acts as a high-pass filter, allowing the 50-500 kHz DGP signal to pass while blocking the 60 Hz power frequency.<\/p>\n<p>A key innovation, protected by U.S. patents, is the use of differential coupling. Instead of using a single phase and a ground return, the DGP system injects the signal across two of the three power phases. This technique provides significant common-mode noise rejection, dramatically improving the signal-to-noise ratio (SNR) and overall system reliability. It also allows the system to function effectively on ungrounded delta systems, which are common on sub-transmission utility networks.<\/p>\n<h2>Signal Regeneration for Extended Reach<\/h2>\n<p>To overcome signal degradation over long distances, DGP employs a sophisticated digital technique called signal regeneration. Unlike traditional analog systems that use simple amplifiers (repeaters) DGP uses a combination of Frequency Division Multiplexing (FDM) and Time Division Multiplexing (TDM) to regenerate the signal. This allows for multiple DGP signals to coexist on the same line at different frequencies and time slots. A regenerator unit receives a weakened signal on one frequency, decodes the digital message and then re-transmits a fresh, full-strength signal on a different frequency and time slot. This process effectively boosts the signal without accumulating noise, enabling the system to cover extensive circuit lengths and overcome signal loss caused by capacitor banks and other inline grid equipment.<\/p>\n<table border=\"1\" width=\"100%\" cellspacing=\"0\" cellpadding=\"0\">\n<tbody>\n<tr>\n<td valign=\"top\">\n<p>Feature<\/p>\n<\/td>\n<td valign=\"top\" width=\"37%\">\n<p>Legacy Power Line Carrier (PLC)<\/p>\n<\/td>\n<td valign=\"top\" width=\"39%\">\n<p>Distributed Generation Permissive (DGP)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Physical Medium<\/p>\n<\/td>\n<td valign=\"top\" width=\"37%\">\n<p>High Voltage Transmission Lines<\/p>\n<\/td>\n<td valign=\"top\" width=\"39%\">\n<p>Medium Voltage Distribution Lines<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Signal Type<\/p>\n<\/td>\n<td valign=\"top\" width=\"37%\">\n<p>Analog Audio Tone<\/p>\n<\/td>\n<td valign=\"top\" width=\"39%\">\n<p>Digitally Encoded Messages<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Signaling Technology<\/p>\n<\/td>\n<td valign=\"top\" width=\"37%\">\n<p>Narrowband FSK<\/p>\n<\/td>\n<td valign=\"top\" width=\"39%\">\n<p>Wideband Modulation<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Frequency Blocking<\/p>\n<\/td>\n<td valign=\"top\" width=\"37%\">\n<p>Required (Wave\/Line Traps)<\/p>\n<\/td>\n<td valign=\"top\" width=\"39%\">\n<p>Not Required (Digital Frequency Separation)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Coupling Method<\/p>\n<\/td>\n<td valign=\"top\" width=\"37%\">\n<p>1-Phase (CC or CCVT)<\/p>\n<\/td>\n<td valign=\"top\" width=\"39%\">\n<p>2-Phase Differential (Capacitive Coupler)<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Output Power<\/p>\n<\/td>\n<td valign=\"top\" width=\"37%\">\n<p>~10W<\/p>\n<\/td>\n<td valign=\"top\" width=\"39%\">\n<p>~0.1W<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">\n<p>Regeneration<\/p>\n<\/td>\n<td valign=\"top\" width=\"37%\">\n<p>No (Single Frequency Operation)<\/p>\n<\/td>\n<td valign=\"top\" width=\"39%\">\n<p>Yes (FDM\/TDM for Extended Reach)<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em>Table 1: A comparison highlighting the key differences between legacy PLC and modern DGP technology.<\/em><\/p>\n<h2>The Next Frontier: Extending DGP to 69kV Sub-transmission<\/h2>\n<p>While DGP has proven its value on medium-voltage distribution systems, applying it to higher-voltage sub-transmission lines presented a new set of challenges. These include:<\/p>\n<ol>\n<li>Higher Voltage: The standard 36kV DGP coupler is not rated for 69kV operation.<\/li>\n<li>Increased Noise: Higher voltage lines typically exhibit higher levels of electrical noise.<\/li>\n<li>Longer Distances: Sub-transmission lines often span much greater distances than distribution feeders.<\/li>\n<li>Networked Topologies: Sub-transmission systems are frequently networked and fed from multiple sources, unlike the typically radial structure of distribution circuits.<\/li>\n<\/ol>\n<p>The research team at GridEdge hypothesized that a standard Coupling Capacitor Voltage Transformer (CCVT), a device already common in high-voltage substations for voltage measurement and traditional PLC applications, could be used as a coupling device for the DGP signal. The first step was to measure the transfer function of a 69kV CCVT. The results were highly encouraging, showing that the CCVT had a compatible frequency response and even a slightly lower insertion loss (1-2 dB) compared to the standard 36kV DGP coupler (3-4 dB).&nbsp;<\/p>\n<p>Following successful lab-based tests on de-energized equipment, the system was tested on energized 69kV lines at a utility test center. These tests confirmed that the DGP modem and its associated circuitry could operate reliably in a high-voltage environment, recovering within seconds after line switching events. A critical lesson learned during this phase was the importance of proper grounding to prevent parasitic signal paths that could degrade performance.<\/p>\n<h2>Real-world Deployment and Success<\/h2>\n<p>With the proof-of-concept validated, the DGP system was deployed in a real-world utility application on a networked 69kV sub-transmission line. The project involved a DER site located between two transmission stations \u2014 approximately 25 miles from one end and 19 miles from the other. To accommodate the networked configuration, a DGP transmitter was installed at each of the two source substations and a single DGP receiver was installed at the DER site.<\/p>\n<p>The protection scheme was designed so that the receiver would only initiate a trip if it lost the permissive signals from both transmitters, a logic that was successfully tested in the lab prior to deployment. During commissioning, a series of trip tests were performed with 100% success. The system demonstrated reliable communication over the 25-mile distance using only 60% of the transmitter\u2019s maximum output power, suggesting that a reach of up to 50 miles is feasible.<\/p>\n<p>The system\u2019s design also inherently handles line faults correctly. For a temporary fault that causes a brief breaker operation and reclose, the signal is lost for less than a second and is re-established before the two-second trip timer expires, preventing a nuisance trip. For a permanent fault, the protection relays at the substation will open the breaker and de-energize the line, which also stops the DGP signal, leading to the desired disconnection of the DER.<\/p>\n<h2>A Cost-effective Path Forward<\/h2>\n<p>The successful extension of DGP technology to 69kV sub-transmission systems marks a significant advancement in grid protection. By leveraging existing, industry-standard CCVTs as coupling devices, the system simplifies engineering and reduces the need for specialized equipment. This approach provides a highly reliable, fail-safe and cost-effective alternative to the expensive and time-consuming installation of dedicated fiber optic lines for DTT.<\/p>\n<p>GridEdge and its manufacturing partner, Custom Electronics Inc. (CEI) offer a 69kV Distributed Generation Permissive (DGP) solution that enables safer, more cost-effective integration of DER into utility grids. The new system addresses this critical safety challenge: protecting utility workers and equipment when distributed energy resources are disconnected from the grid and form an unintentional island that may cause dangerous power fluctuation.&nbsp;<\/p>\n<p>As more large-scale renewable energy projects seek to interconnect at the sub-transmission level, solutions like the DGP system are crucial for accelerating their deployment. By providing a secure and dependable method for islanding protection, this technology helps ensure the stability and safety of the grid while paving the way for a cleaner energy future.<\/p>\n<p><strong><a href=\"https:\/\/blockads.fivefilters.org\"> <\/a><\/strong> <a href=\"https:\/\/blockads.fivefilters.org\/acceptable.html\"> <\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>&#8230; probability of false trips. The <span class=\"match\">Technology<\/span> Behind DGP\u00c2\u00a0 The effectiveness of &#8230; Tone Digitally Encoded Messages Signaling <span class=\"match\">Technology<\/span> Narrowband FSK Wideband Modulation Frequency &#8230; method for islanding protection, this <span class=\"match\">technology<\/span> helps ensure the stability and &#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"fifu_image_url":"","fifu_image_alt":"","footnotes":""},"categories":[1],"tags":[],"class_list":["post-85226","post","type-post","status-publish","format-standard","hentry","category-news","wpcat-1-id"],"_links":{"self":[{"href":"https:\/\/new7.shop\/zerocostfreehost\/index.php\/wp-json\/wp\/v2\/posts\/85226","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/new7.shop\/zerocostfreehost\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/new7.shop\/zerocostfreehost\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/new7.shop\/zerocostfreehost\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/new7.shop\/zerocostfreehost\/index.php\/wp-json\/wp\/v2\/comments?post=85226"}],"version-history":[{"count":0,"href":"https:\/\/new7.shop\/zerocostfreehost\/index.php\/wp-json\/wp\/v2\/posts\/85226\/revisions"}],"wp:attachment":[{"href":"https:\/\/new7.shop\/zerocostfreehost\/index.php\/wp-json\/wp\/v2\/media?parent=85226"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/new7.shop\/zerocostfreehost\/index.php\/wp-json\/wp\/v2\/categories?post=85226"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/new7.shop\/zerocostfreehost\/index.php\/wp-json\/wp\/v2\/tags?post=85226"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}